RJ8-7110-Spartan
Spartan Chemical Company, Inc.
Material Safety Data Sheet
SECTION I: PRODUCT INFORMATION
Product Name or Number (as it appears on label): |
Product Division: |
RJ8
Product Number: 7110; 7111 |
Janitorial |
Spartan Chemical Company, Inc. |
Product/Technical Information: |
1-(800)-537-8990 |
1110 Spartan Drive |
Medical Emergency: |
1-(888)-314-6171 (24 hours) |
Maumee OH 43537 |
Chemical Leak/Spil Emergency: |
CHEMTREC 1-(800) 424-9300 (24 hours) |
Shipping Description: |
Compounds, cleaning liquid, 8, NA 1760, III, (contains sodium hypochlorite, sodium hydroxide) for 55 gal., ORM-D, Consumer commodity, cleaning compounds, liquid, n.o.s. excluding 55 gal. |
NFPA Ratings: |
|
HMIS Ratings: |
|
Health: |
2 - Moderate |
Health: |
2 - Moderate |
Fire: |
0 - Minimal |
Fire: |
0 - Minimal |
Reactivity: |
0 - Minimal |
Reactivity: |
0 - Minimal |
|
|
Pers. Prot. Equip.: |
B - Safety Glasses; gloves |
SECTION II: HAZARDOUS INGREDIENTS
(Listed when present at 1% or greater, carcinogens at 0.1% or greater) All component chemicals are listed or exempted from listing on the "TSCA Inventory" of chemical substances maintained by the U.S. Environmental Protection Agency.
Chemical Name(s) |
% W
|
CAS Registry No.
|
Table Z- 1 - A
|
Carcinogen
|
TWA mg/m3
|
STEL mg/m 3
|
CELING mg/m3
|
Sodium hypochlorite |
1-3
|
7681-52-9
|
Not Established
|
Not Established
|
Not Established
|
No
|
Sodium hydroxide |
<1
|
1310-73-2
|
2
|
Not Established
|
Not Established
|
No
|
SECTION III: PHYSICAL DATA
Boiling Point: |
210 °F |
Vapor Pressure: |
18 mm Hg @ 75°F |
Vapor Density (AIR = 1): |
Unknown |
Solubility in Water: |
Complete |
pH: |
13.0-13.2 |
Specific Gravity (H2O=1): |
1.042 |
Evaporation Rate (but.ace.=1): |
<1 |
Percent Solid by Weight: |
7-8 |
Physical State: |
Liquid |
|
|
Appearance & Odor: |
Clear yellow liquid, Clean mint fragrance |
SECTION IV: FIRE & EXPLOSIVE HAZARD DATA
Flash Point: |
None |
Method Used: |
ASTM-D56 |
Flammable Limits: |
Not Established |
Flame Extension: |
N/A |
Extinguishing Media: |
N/A |
Special Fire Fighting Procedures: |
None |
Unusual Fire & Explosive Hazards: |
None known |
SECTION V: HEALTH HAZARD DATA
Threshold Limit Value: |
Not Established |
Primary Routes of Entry: |
Skin Contact |
Effects of Overexposure-
Conditions to Avoid: |
Severe eye irritant. May cause skin irritation. Irritation to mucous membranes may occur if the product is misted or inhaled. Avoid contact with skin and eyes. Not recommended for use by persons with heart conditions or chronic respiratory problems such as asthma, emphysema or obstructive lung disease. |
Conditions Aggravated by Use: |
Use of this product may aggravate preexisting respiratory or heart conditions. |
Emergency & First Aid Procedures:
Eyes: |
In case of contact; immediately flush eyes with water for at least 15 minutes. Remove contact lenses. Call a physician. |
Skin: |
In case of contact; flush skin with water. Wash clothing before reuse. |
Ingestion: |
If swallowed; drink large quantities of water. Do not induce vomiting. Call a physician immediately. |
SECTION VI: REACTIVITY DATA
Stability: |
Stable |
Incompatible Materials: |
Acids; ammonia; oxidizable materials |
Hazardous Decomposition Products: |
Hypochlorous acid, chlorine |
Hazardous Polymerization: |
Will Not Occur |
SECTION VII: SPILL OR LEAK PROCEDURES
Steps to be Taken in Case
Material is Released or Spilled: |
Flush with copious amounts of water into sanitary sewer system. |
Waste Disposal Method: |
Same as above |
SECTION VIII: SPECIAL PROTECTION INFORMATION
Respiratory Protection: |
None required |
Ventilation: |
Good general ventilation should be sufficient for most conditions. Local exhaust ventilation may be necessary for some operations. |
Protective Gloves(Specify Type): |
Rubber or water-proof gloves |
Eye Protection(Specify Type): |
Safety glasses |
Other Protective Equipment: |
None |
SECTION IX: SPECIAL PRECAUTIONS
Precautions; Handling & Storing: |
None |
Other Precautions: |
None |
© SCC 11/15/1999 |
Name: |
Ronald T. Cook |
Title: |
Manager, Regulatory Affairs |
RJ8 |
Effective Date: |
11/15/1999 |
Supercedes: |
09/28/1999 |
Ref: 29 CFR 1910.1200 (OSHA) |
Changes: |
Correct shipping description |
This document has been prepared using data from sources considered technically reliable. It does not constitute a warranty, express or implied, as to the accuracy of the information contained herein. Actual conditions of use and handling are beyond sellers control. User is responsible to evaluate all available information when using product for any particular use and to comply with all Federal, State and Local laws and regulations. |